Split Ezy Pro Quick Installation Guide
30 May 2022Property owners have been opting for split air conditioning systems due to their associated benefits.
For one, these systems can operate more quietly than other types of air conditioning systems. The outdoor unit of split air conditioning systems houses the condenser, which generates operating sound. Since it will be installed outside, property owners can expect their rooms to be quiet. Another benefit of these systems is they are cost-effective. Split air conditioning systems can cool rooms and spaces quickly without spending too much energy. Other benefits of these systems include ease of installation, appealing design, and straightforward operation.
The installation of split air conditioning systems can be easy. However, a high-quality bracket must be present to ensure its effectiveness.
Basic Features of Split Ezy Pro
One notable split air conditioning system bracket that property owners like you can install is the Split Ezy Pro. Split Ezy Pro is a protective and time-saving installation bracket that can fit almost all makes and models of split system air conditioning units.
What is great about this specific bracket is it can easily protect pipes, cables, and drain from potential theft and external damage during construction works. It can also provide split air conditioning units with a way to be installed on plaster battened walls. Split Ezy Pro likewise has a visual datum point to effectively locate brackets and pipes behind finished wall lining.
Ultimately, Split Ezy Pro can be installed conveniently.
Split Ezy Pro Installation Guide
When installing Split Ezy Pro, the first step is to measure the bracket. Doing this can help the installer know its measurements. The installer can then set some markings on the wall based on the bracket’s dimensions. Afterwards, the installer should mark and cut out the stud to make room for the Split Ezy Pro bracket. The bracket must subsequently be placed flush with the front of the studs.
Upon placing the bracket, the installer should bend out the datum spike and the tabs. Before installing the pipes, some portions of the bracket must be cut so they can fit conveniently. The pipes and cables can then be installed into the bracket. Once installed, the tabs should be bent back.
The installer should then plaster over the Split Ezy Pro to ensure the penetration of the datum spike. The datum spike exists so that the installer can use it as a guide to level and mark the template. The marked template should be consequently cut out to fit the air conditioning system. After cutting the template out, the datum spike must be removed, while the tabs must be pushed back. Pipes should be pulled out so that the air conditioning unit bracket can be affixed with self-tapping screws.
The pipes must be cut before installing the air conditioning unit.
Spit Ezy Pro is not suitable for fire-rated wall penetrations. If you want to maximise brackets for these applications, you may want to opt for Split Ezy Fire. You can also contact us at Split Ezy Pro to know more about these split air conditioning unit brackets.