Contractors that are part of the construction industry must ensure that their projects will be done properly. Hence, they would often opt for materials that can make the buildings and structures last longer.

But even with reliable materials, some buildings and structures can still obtain some damages. They can even cause devastating problems that can risk not only the structural integrity of these properties but also the lives of the people residing or working inside them. One of the devastating problems that have damaged and injured a lot of people is property fire.

A fire can be caused by faulty electrical equipment, unchecked cooking appliances, and others. The effects of this problem, however, can still be minimised if building safety protocols and regulations are followed. Three major risks related to buildings violating essential safety measures are as follows:

  1. Rapid Surface Propagation

One of the building regulations that must be followed by contractors is the proper placement of compatible cladding systems. A cladding system refers to building structure components that can provide thermal insulation, weather resistance, noise control, and other positive effects to a specific building or structure. If the materials used for the cladding system are not reviewed thoroughly, the said system might allow the fire to spread quickly, especially on the external surface of a property. With rapid surface propagation of fire, a building or structure can be quickly filled with fire in just under 15 minutes.

  • Re-entry of Fire

Windows, doors, and other existing openings on a building or structure can serve as the entryways for the fire. Without any mitigating components attached or installed on these openings, a property fire is expected to engulf the property very quickly. Worse, secondary fires can be developed in property areas far from the source of fire, especially if the building does not have any fire-stopping elements installed in property openings. Once secondary fires start, occupants who are still inside the building may be trapped, making it difficult for them to escape.

  • Fire within the Cavities

One more major risk of a building violating fire safety protocols and regulations is the entry of fire into the cavities. Cavities inside the building are often included in the overall design and formation of the cladding system, ensuring that the property can be insulated properly. But aside from the incorporated cladding system, cavities can also be generated once a fire occurs. No matter what materials are used for the cladding system, a fire can still enter the system and stretch up to 10 times the flame length to secure enough oxygen. This incident can be dangerous since hidden fires and toxic smoke can occur. If you want to make your property safe from fire, feel free to call us at Split Ezy Pro. We offer Split Ezy Fire, an innovative split system air conditioner unit wall mount bracket with an integral fire rated intumescent penetration seal, to make your property safe and efficient.